Arc Flash Safety Tips
An arc flash is a flashover of electric current that leaves its intended path and travels through the air from one conductor to another, or to ground. The results are often violent, including serious injury and death. By some estimates, 30,000 arc flash incidents occur annually in the U.S., resulting in as many as 400 fatalities. Here’s some information and advice on arc flash safety hazards from OSHA.
Arc Flash Causes
Arc flash can be caused by many things including:
– Dust
– Dropped tools
– Accidental contact
– Condensation
– Material failure
– Corrosion
– Faulty Installation
Three Factors Determine Injury Severity:
– Proximity of the worker to the hazard
– Temperature
– Time for circuit to break
Typical Arc Flash Results:
– Burns (Non Flame-Resistant clothing can burn onto skin)
– Fire (could spread rapidly through building)
– Flying objects (often molten metal)
– Blast pressure (upwards of 2,000 lbs. / sq.ft)
– Sound Blast (noise can reach 140 dB – loud as a gun)
– Heat (upwards of 35,000 degrees F)
What Employers Must Do to Protect Employees from Arc Hazards
In general, employers must:
– Assess the workplace to identify employees exposed to hazards from flames or from electric arcs
– Estimate the incident heat energy of any arc hazard
– Ensure that employees exposed to hazards from flames or electric arcs do not wear clothing that could melt onto their skin or that could ignite and continue to burn
– Ensure the outer layer of clothing is flame resistant under certain conditions
– With certain exceptions, ensure that employees exposed to hazards from electric arcs wear protective clothing and other protective equipment with an arc rating greater than or equal to the estimated heat energy
– Provide flame-resistant and arc-rated clothing and other arc-flash protective equipment as required by the electric power generation, transmission and distribution standards.
Arc Flash Protection Methods include:
– De-energize the circuit
– Insulation
– Guarding
– Barricades
– Ground Fault Circuit Interrupters (GFCI)
– Grounding (secondary protection)
– Flame-resistant (FR) clothing rated for relevant heat exposures. The FR clothing industry has developed a heat energy rating system for FR fabrics. To identify the appropriate FR clothing to use, the heat energy, measured in calories per square centimeter (cal/cm2), to which workers are exposed needs to be calculated.
Required Arc Flash Warning Labels
Each piece of equipment operating at 50 volts or more and not put into a deenergized state must be evaluated for arc flash and shock protection. This evaluation will determine the actual boundaries (i.e. prohibited, limited, restricted, etc.) and will inform the employee of what PPE must be worn.
Once the evaluation is complete an Arc Flash Hazard warning label must be affixed to the equipment and readily accessible to employees who may work on the energized equipment.
Additional Arc Flash Safety Resources:
- Visit the OSHA Electric Power Generation, Transmission and Distribution Standard page for more arc flash information.
- Read more from OSHA on fire resistant clothing PPE.
- Browse Arc Flash Safety Labels.